(b) Using the wrenchette, turn lower mounting ring until all 3 mounting tabs latch over the ridges on the slide-up ramps. (a) Lifting disposer from the bottom, (1) hang disposer by aligning 3 mounting tabs on lower mounting ring with slide-up ramps on mounting ring and (2) slightly turn disposer counter clockwise until discharge tube is aligned with plumbing. Insert discharge tube into tailpipe mount and secure with spring clamp.Ħ. Insert Anti-vibration Tailpipe Mount into discharge outlet of disposer. (b) Models with Anti-vibration Tailpipe Mount: If label is present on discharge, remove. NOTE: Although the supplied curved discharge tube is preferred, a straight discharge tube may be used but should be installed with a slight downward pitch to avoid risk of water leakage. Secure tailpipe gasket/flange assembly with bolts. Slide flange over discharge tube and insert tailpipe gasket into discharge outlet of disposer. (a) Models with tailpipe gasket/flange: If label is present on discharge, remove. You may need to trim the discharge tube to ensure proper fit. (g) Install and tighten ground screw through cord and into bottom of disposer.ĭO NOT insert fingers into discharge opening. Insert EZ Connect Power Cord into cutout on bottom of disposer and push forward to connect power to disposer. It should not be used with a standard 3-prong power cord.Ĭorded Unit: (f) Remove ground screw from bottom of disposer. NOTE: EZ Connect Hardwire Adapter is designed to work with a Romex or BX cable. Install and tighten ground screw through the cover plate and into bottom of disposer. Insert the adapter/cover plate assembly into cut-out on bottom of disposer and push assembly forward to connect power. Remove the ground screw from the bottom of the disposer. Align and push adapter onto cover plate until plastic latch locks into the plate's slot. (d) Bend adapter downward (approximately 90°). Insert wires into proper locations on adapter and push to lock. Verify proper wire connection locations on side of hardwire adapter: Live (black wire), Ground (green/bare wire), Neutral (white wire). (c) Insert cable with prepped wiring through strain relief/cover plate assembly. From the bottom, (1) install threaded portion of strain relief into cover plate and (2) secure from above with nut. Verify correct length with arrow embossed on underside of EZ Connect Hardwire Adapter. Hardwired Unit: (a) Prep wiring so that 1-3/8" extends from the jacket.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |